11.4. Default Settings 3: Communication Settings
11.4.1. Default Settings 3A: Serial Communication Settings— RS-232C
Parameter “U2” Default Setting
Baud rate 9600 bps
Parity bits No parity
Data length 8 bits
Stop bits 1 bit
Handshaking None
ACK/NAK None
Flow Control time out Infinite
ACK/NAK timeout 1 second
Command header ESC or STX
Command terminator CR or ETX
ACK/NAK for RS232 Comm. None
11.4.2. Keyboard Communication Settings—USB
Parameter “SU”/”C01” Settings
Scanner power: Max power descriptor 100mA
Keyboard *1 US Keyboard
Vendor ID 0x65a (OPTOELECTRONICS)
Transmit Enter key output*1 Enable
Transmit Execution key output*1 Disable
Transmit Tab key output*1 Disable
Transmit Arrow right key output*1 Disable
11.4.3. Keyboard Communication Settings—Wedge
Parameter “UB” Settings
Transmit Enter key output as a suffix Enable
Transmit Execution key output as a suffix Disable
Transmit Tab key output as a suffix Disable
Transmit Arrow right key output as a suffix Disable
Delay after transmission 10 ms
Scan code Scan code set 2 (keyboard)
Select keyboard US keyboard emulation

Table of Contents