EasyManua.ls Logo

Opticon OPR 3201 - Scan Area and Resolution; Depth of Field

Opticon OPR 3201
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Opticon
OPR 3201
Specifications Manual
15
8.3. Scan Area and Resolution
8.3.1. Depth of Field
The depth of field is measured from the edge of the scanner. The scanning range
is within the circular arc centered on the scan origin.
Figure 6: Depth of field
Symbology Resolution Decode Depth (mm) PCS
Code 39 1.0 mm 40–500 0.9
Code 39 0.5 mm 20–350 0.9
Code 39 0.25 mm 20–200 0.9
Code 39 0.15 mm 20–100 0.9
Code 39 0.127 mm 30–70 0.9
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
N/W Ratio 1:2.5
Angle α = 0°, β = 15°, γ = 0°
Curvature R =

Table of Contents

Related product manuals