6.2. Electrical Characteristics
Interface Parameter Min Typ Max Unit Notes
Operating voltage 4.5 6.0 6.6 V
Operating current 100 160 mA 100 mA—Laser: ON, Buzzer: OFF
160 mA—Laser: ON, Buzzer /LED:ON
Rush current 550 600 mA Power supply voltage: 6.0 V
RS-232C
Stand-by current 35 65 mA Auto trigger OFF/ON
Operating voltage 4.5 5.0 5.5 V
Operating current 100 160 mA 100 mA—Laser: ON, Buzzer: OFF
160 mA—Laser: ON, Buzzer /LED:ON
Rush current 450 500 mA Power supply voltage: 5.0 V
USB
Wedge
Stand-by current 35 65 mA Auto trigger OFF/ON
Conditions
Connect 1 resistance to a power supply line in series and measure the current by the
voltage between both ends of resistance.
Power supply voltage is measured at a connector terminal area.
The current value depends on the interface type and host computer to which the device is
connected.
6.3. AC Adapter
The OPR 3201 with RS-232C serial interface is shipped with a dedicated AC adapter
“Universal AC Adapter Kit.” Plug connectors can be changed for each region. See
diagrams below.
Item Specification
Model Name SFP0602000P-PSE
Dimensions 47.5 (W) × 28.0 (D) × 75.0 (H) mm
DC output cable length 1.8m
Voltage range AC 90 to 265 V
Input specifications
Supply current 0.5 A max
Voltage range 5.7 to 6.3 V
Output Specifications
Maximum current 2 A max
Operating temperature 0 to 40°