Oracle Database Appliance X6-2S/X6-2M/X6-2L Status Indicators
14 Oracle Database Appliance Service Manual • June 2017
Server Back Panel Status Indicators
The Oracle Database Appliance X6-2S/X6-2M server back panel includes indicators for the
system, power supplies and network ports.
Callout Indicator/LED: Color State Meaning
1, 3 PS Service Required: amber Off – Normal operation.
On – The power supply (PS) has detected a PS fan failure, PS
overtemperature, PS over current, or PS over or under voltage.
2, 4 PS OK: green Off – No AC power is present.
On – Normal operation. Input AC power and DC output voltage
are within specification.
Slow blink – Normal operation. Input power is within
specification. DC output voltage is not enabled.
5 System locate, service required
and OK: various
These operate in the same way as on the front panel.
6 NET MGT port: green 10/100/1000 BASE-T Ethernet management interface.
Top left link indicator:
On – Green for 1000Base-T link.
Off – 10/100BASE-T link.
Top right activity indicator:
On – Link up.
Off – No link or link down.
Blinking – Packet activity.
7 NET 0-3 ports: green/amber 100/1000/10000 BASE-T Ethernet management interface.
Top left activity indicator:
On – No function.
Off – No activity.
Blinking – Packet activity.
Top right link indicator:
On – Amber for 1000Base-T link; green for 10GBBase-T link.
Off – 100BASE-T link.