Oracle Database Appliance Version 1 Hot-Pluggable Components
Chapter3 • Servicing CRUs That Do Not Require System Power Off 75
Hot-pluggable components are those that can be removed and installed while the system and the
server nodes are running. These are designated as Customer Replaceable Units (CRUs).
In Oracle Database Appliance Version 1, the following devices are hot-pluggable:
■
Storage and Boot Drives. See “Servicing Storage Drives and Boot Drives
(CRU)” on page 118.
■
Fan modules. See “Servicing Fan Modules (CRU)” on page 125.
■
Power supplies. See “Servicing Power Supplies (CRU)” on page 128.
Note - After a physical insertion or removal action of a storage component (such as a disk or
SAS cable), you should wait before performing the next action to allow the system software to
fully process the event. This could take up to 3 minutes to complete.
Note - For the Oracle Database Appliance Version 1, you must run the oakcli add disk -
local command after replacing a failed disk. Refer to the Administration and Reference Guide
for details.