6.Specification
81
Distortion
Second harmonic cut-off point
Second harmonic
cut-off pointSHI
fc ≥ 50 MHzinput signal level is -20 dBm
attenuator is 10 dB
+45 dBm
Third order intermodulation cut-off point
Third order
intermodulation cut-off
pointTOI
fc ≥ 50 MHztwo magnitudes are -20 dBm
frequency interval 200 kHz Two-tone signal
input mixerattenuator is 0 dB
+14 dBmTypical
1dB Gain compression
Input the 1dB
compression point of
the mixerP1dB
fc ≥ 50 MHzattenuator is 0 dB
-2dBmnominal