Inspections and maintenance
1. Switch the ignition on by turning the ignition key to position D (M).
2. The indicator light will glow (situation B in the drawing) indicating the system is
activated.
3. Wait five seconds.
4. If after these five seconds, when the indicator light is on brightly (situation A in the
drawing), draining is necessary.
5. Check the reservoir (5) for water.
NOTE: Perform these actions while the engine is not running.
6. If necessary, open the drain plug (6) and pump the water out using the lift pump (1).
7. Close the drain plug (6).
8. Open the bleed screw (2) on the filter housing.
9. Use the lift pump (1) to pump fuel through the system until there are no air bubbles
in the fuel flowing out of the bleed screw.
10. Close the bleed screw (2).
DW63246305.book Page 179 Friday, March 22, 2019 4:54 PM