196
SEP 2004
Ver. 1.2
DP-1520P/1820P/1820E
5.1.5. F6 Mode: Adjust Parameters (For Copier)
Set the machine to Service Mode and press "6" key on the Keypad.
↓
Press the "START" key.
↓
Enter the desired code number or press “V”, ”/\” arrow keys.
↓
If you wish to select another code number, scroll the menu with the arrow keys.
↓
Press the "SET" key.
↓
Enter the desired function code number and press “SET” key.
↓
When the “CLEAR” key is pressed, the selected code input will not be accepted.
↓
Press “STOP” key, then press “FUNCTION” and “CLEAR” keys simultaneously to exit the service mode.
↓
Reboot the machine after setting the parameter(s) to activate the setting(s).
Note:
The Factory Setting is different in each model.
F6 Mode
No. Item Remarks
Setting
Range
00 Adj 100% Side-Side Read Adjustment for identical vertical (side-to-side)
size ratio.
-9 - +9 0.1%
01 Adj 100% Lead-Tail Read Adjustment for identical horizontal
(top-to-bottom) size ratio.
-9 - +9 0.1%
02 100% Selection Adjustment from 99.1% to 100.9% -9 - +9 0.1%
03 Original Registration Adjustment of platen original registration
detection timing.
-30 - +30
0.2mm
04 Printer Registration Delay time is adjusted from registration roller
clutch ON.
-50 - +50
0.5mm
05 Main Motor Speed Adjustment of Main Motor speed. -10 - +10
0.1%
06 Polygon Motor Speed Adjustment Polygon Motor speed. -5 - +5 0.1%
07 Registration Void Registration void should be adjusted. 0 - +99
0.5mm
08 Trail Edge Read Timing Adjustment of trail edge void. -9 - 0
0.5mm
09 Trail Edge Print Timing Adjustment of trail edge void. -9 - +15
0.5mm
10 Side Adjust (Bypass) Adjustment of LSU side-side (Sheet Bypass). -8 - +7
0.5mm
11 Side Adjust (Tray 1) Adjustment of LSU side-side (1st Tray). -8 - +7
0.5mm
12 Side Adjust (Tray 2) Adjustment of LSU side-side (2nd Tray). -8 - +7
0.5mm
13 Side Adjust (Tray 3) Adjustment of LSU side-side (3rd Tray). -8 - +7
0.5mm