EasyManua.ls Logo

Panasonic DP-8032 - Page 158

Panasonic DP-8032
397 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
158
DP-8032/8025
2008Ver.1.2
421 RCV B Busy Tone is detected after
sending NSF Signal.
Remote station disconnected the line.
Wrong number dialed.
422 XMT B Content of NSF (or DIS) or NSC
(or DTC) was invalid.
Incompatible content
427 G3
RCV
B DCN received to NSF/CSI/DIS
transmitted.
Interface is incompatible.
433 XMT
RCV
B, D T.30 Protocol abnormal. Defective remote station.
434 XMT or RCV B CD (response from Modem) did
not turn OFF within 180 sec. after
receiver detected FLAG signal.
Remote unit defective.
FXB PCB or MJR PCB defective.
436 G3 RX C DCN received after transmitting
FTT.
Transmitter defective or incompatible.
Line quality poor.
438 RCV B Refusal ID (Junk Fax ID) received
in Phase B.
Transmitter ID is registered as a Junk
Fax. JUNK is printed as the
Information Code on the Comm.
Journal.
456 RCV B Received relay transfer request or
confidential document to distribute
to an end receiving station or all
confidential mailboxes are used.
457 RELAY XMT
CONF. XMT/
POLL
B Remote unit does not have
Relayed XMT or Confidential
Comm. capability.
459 RCV C Failed training in Phase C. Line quality poor. (Training signal
distorted due to line noise)
FXB PCB or MJR PCB defective.
490 RCV C Sum of error lines exceeded the
limit (Function Parameter No. 70)
of 64 lines.
Line quality poor.
FXB PCB or MJR PCB defective.
494 RCV C Interval between two EOLs was
more than 10 sec. when receiver
received message data.
Transmitter defective.
Line quality poor. (EOL damaged due
to line noise)
FXB PCB or MJR PCB defective.
495 XMT
RCV
C During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line disconnected.
Transmitter defective.
FXB PCB or MJR PCB defective.
496 XMT C CS of modem is not able to turn
ON.
FXB PCB defective.
501 XMT/
RCV(V.34)
B Incompatible Modem on the
Remote unit.
502 XMT/
RCV(V.34)
B, C, D During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line disconnected.
Transmitter defective.
FXB PCB or MJR PCB defective.
503 XMT/
RCV(V.34)
B, C, D CS of modem is not able to turn
ON during training.
FXB PCB defective.
Line disconnected.
504 RCV/V.34
(Polling)
B Polling is rejected from the remote
station.
No polling original set.
505 XMT/V.34
(Polling)
B Polling XMT is rejected. No polling original set.
Fax Information Codes
Code Mode Phase Description of Problem Possible Cause(s)

Table of Contents