3.6. Lubrication Point List
This information is used for routine Preventive Maintenance (PM) calls to ensure the highest degree of
reliability. Inspect the following areas and lubricate as required. The inspection interval is usually 120K
copies or more, however the interval may be reduced due to environmental conditions.
Mechanical Parts
Ref.
No.
Grease Lubrication Point
Fuser Unit
Pressure Spring 1029 EM-50L
Shoulder Screw 1033
Idle Roller 1049 EM-50L
Pinch Shaft 1068
Dual-Path Exit Guide
Top Duplex Guide 1406 EM-50L
Pinch Spring 1411
Pinch Roller 1518
Idle Roller Plate
Spring
1509 EM-50L
Idle Roller 1511

Table of Contents