110 Paper Feed Motor Feed Motor rotates. 1Bin Finisher (FS300)
No. 110-116 (3014)
111 Paper Alignment Motor Paper Alignment Motor drives the Alignment
Plate.
(2931)
112 Paper Tray Lift Motor Paper Tray Lift Motor drives the Paper Tray up
and down.
(2511)
113 Stapler Motor Stapler Motor rotates 2 sec. cycle. ---
114 Paddle Solenoid Solenoid turns ON/OFF 500 msec. cycle. (2728)
115 Large Gear Solenoid Solenoid turns ON/OFF 500 msec. cycle. (2610)
116 Paper Hold Lever
Solenoid
Solenoid turns ON/OFF 1 sec. cycle. (2613)
117-
119
Not Used
120 Lamp When SDR PCB CN656-1 signal level changes to
0V from +5V, Lamp operates.
(204)
121-
159
Not Used
160 ADF Motor Rotating
(35% speed rotating)
ADF motor rotates at 35% speed. (1801)
161 ADF Motor Rotating
(100% speed rotating)
ADF motor rotates at 100% speed. (1801)
162 ADF Motor Rotating
(400% speed rotating)
ADF motor rotates at 400% speed. (1801)
163 ADF Motor Reverse
Rotating
(35% speed rotating)
ADF motor rotates in reverse at 35% speed. (1801)
164 ADF Motor Reverse
Rotating
(100% speed rotating)
ADF motor rotates in reverse at 100% speed. (1801)
165 ADF Motor Reverse
Rotating
(400% speed rotating)
ADF motor rotates in reverse at 400% speed. (1801)
166 ADF Paper Feed Roller
Clutch 1
When ADF PCB CN22-10 signal level changes to
0V from +24V, clutch operates for 3 seconds.
(1788)
167 ADF Paper Feed Roller
Clutch 2
When ADF PCB CN22-8 signal level changes to
0V from +24V, clutch operates for 3 seconds.
(1787)
168 ADF Paper Feed Roller
Clutch 3
When ADF PCB CN24-2 signal level changes to
0V from +24V, clutch operates for 3 seconds.
(969)
169 ADF Paper Exit Solenoid When ADF PCB CN26-2 signal level changes to
0V from +24V, Solenoid operates for 3 second.
(1762)
170-
171
Not Used
172 ADF Solenoid When ADF PCB CN26-5 signal level changes to
0V from +24V, Solenoid operates for 1 second.
(1770)
173 ADF Inverting Solenoid When ADF PCB CN26-3 signal level changes to
0V from +24V, Solenoid operates for 1 second.
(1770)
174 ADF Pinch Roller
Solenoid
When ADF PCB CN26-7 signal level changes to
0V from +24V, Solenoid operates for 1 second.
(1762)
175 ADF Stamp Solenoid When ADF PCB CN25-2 signal level changes to
0V from +24V, Solenoid operates for 1 second.
(1635)
F4 Mode (Output Check)
No. Item Function
Remark