192
DP-8032/8025
2008Ver.1.2
80 QUANTUM Photo Mode Read Value of QUANTUM Gamma Table for Photo Mode. +1 ~ +5
(Read Only)
81 QUANTUM Halftone Read Value of QUANTUM Laser duty of Check pattern. +127 ~ +255
(Read Only)
82 QUANTUM Black Read Value of QUANTUM Laser duty of Black pattern. +127 ~ +255
(Read Only)
83 Temperature Sensor Value Value of Temperature sensor. 0 ~ 255
(Read Only)
84 Humidity Sensor Value Value of Humidity sensor. 0 ~ 255
(Read Only)
85 Not Used
86 ADF Reverse Stop Posi. Adjustment of ADF reverse stop position. -99 ~ +99
0.3 mm
87 ADF Exhaust Stop Posi. Adjustment of ADF exit stop position -99 ~ +99
0.3 mm
88-89 Not Used
90 ADF Read Main Scan Pos. Adjustment of ADF horizontal image read start
position.
-99 ~ +99
0.05 mm
91 Original Read Edge ADF Adjustment of original detection timing. -99 ~ +99
0.3 mm
92 Original Trail Edge ADF Adjustment of trail edge detection timing. -127 ~ 127
0.3 mm
93 ADF 100% Image 1-Sided Adjustment of magnification for 1-sided. -9 ~ +9
0.1 %
94 ADF 100% Image 2-Sided Adjustment of magnification for 2-sided. -9 ~ +9
0.1 %
95 Manual Photo Adj. Adjustment of Gamma Table Value for Photo Mode
(QUANTUM OFF)
+1 ~ +5
96 Manual Halftone Adj. Adjustment of Laser duty of Check pattern for Text
and Text/Photo Mode. (QUANTUM OFF)
+127 ~ +255
97 Manual Black Adj. Adjustment of Laser duty of Black pattern for Text
and Text/Photo Mode. (QUANTUM OFF)
+127 ~ +255
98 Not Used
99 F5/F6 Initialization Initialize F5/F6 parameter settings.
F6 Mode
No. Item Remarks
Setting
Range