441
DP-C405/C305/C265
FEB 2008Ver. 1.1
044 Redial Count 0 = no redial
~
15 = 15 times
0 ~ 9 (For Australia Only)
Selects the redial count from 0 to 15 times in 1 step
intervals.
Note:
In order to comply with the requirements TBR21 in
the EC countries, do not select 15 times.
045 Ring Detect
Count
1 = 1 ring
~
9 = 9 rings
Selects the ring detection count from 1 to 9 rings in 1
ring step intervals.
046 On-Hook Time 0 = 0 sec.
~
90 = 90 sec.
Selects the on-hook time between sequential
communication calls in 1 second step intervals.
047 Response Wait
Interval
1 = 1 sec.
~
90 = 90 sec.
20 ~ 150 sec.
(For France Only)
Selects the waiting interval for the response after
completing the dialing.
048~
049
Not Used
050 Ring Detect Mode Normal
Rough
Selects the quality of ringer detection. Use if the line
signal is out of regulation, set to "Rough" so that the
unit may detect the ringing signals.
051 Not Used
052 Pulse Rate 10 pps
20 pps
Selects the dial pulse rate 10/20 pps.
053~
054
Not Used
055 Busy Tone Check Off
On
Selects whether to detect the Busy Tone.
056 Dial Tone Check Off
On
Selects whether to detect Dial Tone before dialing the
telephone number.
057 DC Loop Check
(Except for USA
and Canada)
Off
On
Selects whether the unit checks the DC Loop during
communication.
058 Comm. JRNL +
Image
Off (without image)
On (with image)
Selects whether the machine prints the COMM.
Journal with image.
059 Confidential RCV
Report
Off (does not print out)
On (prints out)
Selects whether the machine prints the Confidential
RCV Report.
060 Version Indicates the FCB
software version.
061 TX/RX/PRT/CPY 00 = Fax Transmit Count
01 = Fax Receive Count
02 = Total Count
03 = Copy Print Count
Displays the transmitted, received, total printed, and
copied document count.
062 Print Counter Off
On
Selects whether to print in the Fax Parameter List,
the counter information that is displayed in the
Function Parameter No. 61.
063~
067
Not Used
Function Parameter Table
No. Parameter Selections Function