(A: Available, N/A: Not available)
Address Name Description
Read-
ing
Writ-
ing
DT90370
Control flag monitor
area
HSC-CH0
When HSC control is executed
by F0 (MV)S, DT90052
instruction, the setting value for
the target CH is stored in each
CH.
A N/A
DT90371 HSC-CH1 A N/A
DT90372 HSC-CH2 A N/A
DT90373 HSC-CH3 A N/A
DT90374
Not used
N/A
N/A
DT90375
Not used
N/A
N/A
DT90376
Not used
N/A
N/A
DT90377
Not used
N/A
N/A
DT90378
Not used
N/A
N/A
DT90379
Not used
N/A
N/A
DT90380
Control flag monitor
area
PLS-CH0
When pulse output control is
executed by F0(MV), DT90052
instruction, the setting value for
the target CH is stored in each
CH.
A N/A
DT90381 PLS-CH1 A N/A
DT90382
Not used
N/A
N/A
DT90383
Not used
N/A
N/A
DT90384
Not used
N/A
N/A
DT90385
Not used
N/A
N/A
DT90386
Not used
N/A
N/A
DT90387
Not used
N/A
N/A
DT90388
Not used
N/A
N/A
DT90389
Not used
N/A
N/A
DT90400
Elapsed
value area
Lower
words
PLS-CH0
Counting area for pulse output
CH0 (Y0, Y1)
A A
DT90401
Higher
words
A A
DT90402
Target
value area
Lower
words
The target value is set when
instructions F171 (SPDH),
F172 (PLSH), F174 (SP0H)
and F175 (SPSH) are
executed.
A N/A
DT90403
Higher
words
A N/A
DT90404
to
DT90409
Not used
N/A N/A
DT90410
Elapsed
value area
Lower
words
PLS-CH1
Counting area for pulse output
CH01(Y2, Y3)
A A
DT90411
Higher
words
A A
DT90412
Target
value area
Lower
words
The target value is set when
instructions F171 (SPDH),
F172 (PLSH), F174 (SP0H)
and F175 (SPSH) are
executed.
A N/A
DT90413
Higher
words
A N/A
DT90414
to
DT90419
Not used
N/A N/A