4.2 I/O Allocation of FP-X0 Control Unit
The I/O allocation of FP-X control unit is fixed.
I/O numbers
FP-X0 L30R control unit
Input (16 points) X0 to XF
FP-X0 L40R control unit
FP-X0 L40MR control unit
Input (24 points) X0 to XF, X10 to X17
FP-X0 L60R control unit
FP-X0 L60MR control unit
Input (32 points) X0 to XF, X10 to X1F
4.3 FP-X Expansion Unit I/O Allocation
The I/O numbers of FP-X expasion unit differ according to the installation position of the unit.
I/O numbers (when installed as the first expansion unit)
FP-X E14YR expansion output unit
FP-X E16X expansion input unit Input (16 points) X300 to X30F
FP-X E16T/16P expansion I/O unit
Output (8 points) Y300 to Y307
FP-X E30 expansion I/O unit
Output (14 points) Y300 to Y30D
I/O numbers (when installed as the second expansion unit)
FP-X E16X expansion input unit Input (16 points) X400 to X40F
FP-X E16T/16P expansion I/O unit
Output (8 points) Y400 to Y407
FP-X E30 expansion I/O unit
Output (14 points) Y400 to Y40D
I/O numbers (when installed as the third expansion unit)
FP-X E16X expansion input unit Input (16 points) X500 to X50F
FP-X E16T/16P expansion I/O unit
Output (8 points) Y500 to Y507
FP-X E30 expansion I/O unit
Output (14 points) Y500 to Y50D