[Time Table Example]
Day 1 start
Lunch start
Day 2 start
Break 1 start
Break 1 end (Day restart)
Night start
Day 1 start
Lunch start
Day 2 start
Break 1 start
Break 1 end (Day restart)
Night start
:
08:00
12:00
13:00
NONE
NONE
16:00
08:00
12:05
13:00
NONE
NONE
16:31
:
11:00
NONE
NONE
NONE
NONE
20:00
11:00
NONE
NONE
NONE
NONE
20:00
:
MON
TUE
:
Time Schedule
Time Table No. (Tenant No.)
1 2 34
00:00
Time Table No.
<Time Service Image of Monday>
08:00 11:00 12:00 13:00 16:00 20:00
Night Day 1 Day 2
Lunch
Night
Night Day 1 Night
08:00
16:00
NONE
NONE
NONE
12:00
08:00
13:00
NONE
NONE
NONE
17:00
:
08:00
12:00
NONE
NONE
NONE
NONE
08:00
13:00
NONE
NONE
NONE
NONE
:
24:00 08:00
Day 1
Night
Night
Day 1
Day 1
Night
Day 1
Day 1
1
2
3
4
Lunch
Lunch
3. Features Using Time Service
The following features can be programmed separately for each time mode:
a. Destination of incoming CO line calls (Direct In Line (DIL)/Direct Inward Dialing (DID)) (® 4.1.7 DIL
(Direct In Line),
® 4.1.6 DID (Direct Inward Dialing))
b. Destination of calls handled by Intercept Routing (® 9.1.11 Intercept Routing)
c. Destination of calls that are overflowed while waiting in a queue for an available agent of an incoming
call distribution (ICD) group (® 9.1.5 ICD Group Features—Overflow)
d. Destination of incoming doorphone calls (® 4.1.12 Doorphone Call)
e. Destination of Operator Calls (® 12.1.5 Operator Features)
f. Toll Restriction (TRS) level of each COS
g. COS numbers which are permitted/restricted to access certain trunk groups (External Call Block) (®
3.1.17 CO Line Access)
h. Outgoing Message (OGM) for Timed Reminder (® 17.1.4 Timed Reminder)
i. Queuing Time Table used by an ICD group (® 9.1.6 ICD Group Features—Queuing)
j. Intercept time for Intercept Routing—No Answer (® 9.1.11 Intercept Routing)
k. Intercept time for DISA Intercept Routing—No Answer (® 4.1.8 DISA (Direct Inward System
Access))
[Programming Examples of DID/DDI Table and DIL Table]
DID/DDI table can be programmed for each DID/DDI number, and a tenant (Time Table) number is
assigned to each DID/DDI number. DIL table can be programmed for each trunk, and a tenant (Time Table)
number is assigned to each trunk.
Document Version 2013-05 Feature Manual 343
17.1.5 Time Service

Table of Contents

Other manuals for Panasonic KX-NCP1000

Related product manuals