4.4 E1 Line Programming
E1 Programming 399
[783] E1 Group-B
Description
Assigns a signal code for Group-B parameters on the E1 line assigned to MFC-R2.
This programme is available for the KX-TD1232 only.
Selection
•Parameter number:
01
(Idle(1)) /
02
(Idle(2)) /
03
(Idle(3)) /
04
(No Billing) /
05
(Busy) /
06
(Unallocated) /
07
(Congestion) /
08
(Out of Service) /
09
(Collect Call Reject)
•Signal code:
00 through 15
(00=Undefined)
Default
Parameter 01 – 01; Parameter 05 – 02; Parameter 06 – 03; Parameter 07 and 08 – 04; Other
parameters – 00
Programming
1.
Enter
783
.
Display: 783 GROUP-B
2.
Press
NEXT
.
Display: Parameter NO?
3.
Enter a
parameter number
.
To enter a parameter number 01, you can also press
NEXT
.
Display example: 01:01
4.
Enter the
signal code
.
To change the current entry, press
CLEAR
and enter the new code.
5.
Press
STORE
.
6.
To programme another parameter, press
NEXT
or
PREV
, or
SELECT
and the desired
parameter number
.
7.
Repeat steps 4 through 6.
8.
Press
END
.
Conditions
Adjust to a setting of the connected telephone company.
Features Guide References
E1 Line Service