2.5 Outside Line Programming
190 General Programming
[413] Flash Time
Description
Assigns the length of the flash time. If your system is installed behind a host PBX, External
Feature Access (EFA) is necessary to obtain their services. To enable it, select a required
hooking signal sending time for the outside line group.
Selection
• Outside line group (TRG) number:
1 through 8,
( =all outside line groups)
• Time (milliseconds):
Disable
(no EFA)
/ 80 / 96 / 112 / 200 / 300 / 400 / 500 / 600 / 700 / 800 / 900 / 1000 / 1100
/ 1200
Default
All outside line groups – 600 ms
Programming
1.
Enter
413.
Display: 413 FLASH TIME
2.
Press
NEXT.
Display: TRK GRP NO?
3.
Enter an
outside line group number.
To enter outside line group number 1, you can also press
NEXT.
Display example: TRG1: 600 msec
4.
Keep pressing
SELECT
until the desired time is displayed.
5.
Press
STORE.
6.
To programme another outside line group, press
NEXT
or
PREV,
or
SELECT
and the
desired
outside line group number.
7.
Repeat steps 4 through 6.
8.
Press
END.
Conditions
• You may disable EFA, if not required. The Flash feature will be in effect in place of EFA.
Programme [414] Disconnect Time is used to select the time required for the Flash
feature.
• The flash time required is determined by the central office or the host PBX lines.
• To assign all outside line groups to one selection, press the key in step 3. In this case, the
display shows the contents programmed for outside line group 1.