2.5 Information about the Other Cards
Installation Manual 81
10-pin Terminal Block
Connection Diagram for External Sensors and External Relays
Power to the external sensor is provided from the DPH2 card and must be grounded through the DPH2 card
as indicated in the diagram below. A pair of "sensor" and "common" lines must be connected to the DPH2
card for each external sensor. The Hybrid IP-PBX detects input from the sensor when the signal is under
100 Ω.
Signal Name Function
RL1b Relay 1
RL1a Relay 1 com
RL2b Relay 2
RL2a Relay 2 com
RL3b Relay 3
RL3a Relay 3 com
RL4b Relay 4
RL4a Relay 4 com
–Reserved
1
10
RL1b
RL1a
RL2b
RL2a
RL3b
RL3a
RL4b
RL4a
5 V
Sensor 4
Sensor 3
Sensor 2
Sensor 1
8
7
6
5
4
3
2
1
Relay 4
Relay 3
Relay 2
Relay 1
10
9
8
7
6
5
4
3
2
1
5 V
10K Ω
2.2K
47K
33 Ω
33 Ω
5 V
5 V
10K Ω
2.2K
47K
33 Ω
33 Ω
5 V
5 V
10K Ω
2.2K
47K
33 Ω
33 Ω
5 V
5 V
10K Ω
2.2K
47K
33 Ω
33 Ω
sensor
common
sensor
common
sensor
common
sensor
common