■Default value of the parameters(1/12)
Pr. Parameter
Cate
gory
Pr. Parameter
Cate
gory
Pr. Parameter
Cate
gory
Pr. Parameter
Pr. Parameter
0 0
Rotational direction setting
1
1
Control mode setting
0
2
Real-time auto tuning setting
1
3
Real-time auto tuning stiffness
set
13
4
Inertia ratio
250
5
Command pulse input
selection
0
6
Command pulse rotational
direction setting
0
7
Command pulse input mode
setting
1
8
Command pulse number per
one motor revolution
10000
9
First command division /
multiplication numerator
0
10
Command division /
multiplication denominator
10000
11
Output pulse counts per one
motor revolution
2500
12
Pulse output logic inversion/output
source selection
0
1st torque limit
500
14
Position deviation excess
setting
100000
15
Absolute encoder setting
1
16
For manufacturer's use
3
17
For manufacturer's use
0
18
For manufacturer's use
0
*2
When checking directly value of parameter-file with a text data etc., it does not show the decimal point.
Ex) Pr6.24 Disturbance observer filter ・・・ Value of Panaterm : 0.53 / Value of parameter-file : 53
The maximum Torque limit value (Pr.0.13,Pr.5.22,Pr.5.25,Pr.5.26) varies by the applicable motor
Can not be used with [A6SG].
MINAS-A6SF/SG SizeV series