ENGLISH - 115
4) Press the <ENTER> button, press as to select [FILTER COUNTER RESET].
5) Press the <ENTER> button.
f [FILTER COUNTER RESET] conrmation is displayed.
6) Press as to select [OK], then press the <ENTER> button.
f The lter usage time is 0 after reset.
Attention
f Do not disassemble the air lter unit.
f When attaching the air lter unit, make sure that the projector is stable, and work in an environment that is safe, even in the event of the air
lter unit dropping.
f Make sure that the air lter unit is properly attached before using the projector. If it is not attached, the projector will suck in dirt and dust
causing a malfunction.
Note
f After cleaning or replacing the air lter, reset the lter counter. Otherwise, the actual lter usage time cannot be conrmed.
f Replace the air lter unit with the new optional Replacement Filter Unit (Model No.: ET-RFL300) if it is damaged or if the dirt does not come
off even after cleaning.
Replacing the unit
Lamp unit
The lamp unit is a consumable component. Refer to “When to replace the lamp unit” (x page 115) for details
about the replacement cycle.
When purchasing the optional Replacement Lamp Unit (Model No.: ET-LAL510), consult your dealer.
Warning
Do not replace the lamp unit when it is hot. (Wait at least one hour after use.)
The inside of the cover can become very hot, take care to avoid burn injuries.
Notes on the replacement of the lamp unit
f A Phillips screwdriver is necessary when replacing the lamp unit.
f Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object.
Handle with care.
f Do not disassemble or modify the lamp unit.
f When replacing the lamp unit, be sure to hold it by the handle because its surface is
pointed and its shape is protruded.
f The lamp may rapture. Replace the lamp unit carefully so the glass fragments of the
lamp do not scatter. While attaching the projector to the ceiling, do not work right
under the lamp unit or do not conduct work while your face is near the lamp unit.
f The lamp contains mercury. When disposing of used lamp units, contact your
local authorities or dealer for correct methods of disposal.
Attention
f Panasonic takes no responsibility for any damage or malfunction of the product resulting from use of lamp units which are not manufactured
by Panasonic. Use only specied lamp units.
Note
f The model numbers of accessories and optional accessories are subject to change without prior notice.
When to replace the lamp unit
The lamp unit is a consumable component. Since its brightness gradually decreases over time, it is necessary to
replace the lamp unit regularly.
Please refer to [PROJECTOR SETUP] menu → [STATUS] → [RUNTIME] → [LAMP] about the usage time of lamp
(x page 71).
The estimated duration before replacement is 20 000 hours, but the lamp may go off before the time above
mentioned has elapsed depending on individual lamp characteristics, usage conditions, and the installation
environment. It is recommended that the Replacement lamp unit be prepared earlier.