Magellan / Spectra SP 18
If a zone is already programmed and you assign a device to the same zone, a wireless zone will overwrite a keypad/hardwire
zone, and a keypad zone will overwrite a hardwire zone.
Zone 13: Input 8 ZX8 Zone 13: Input 3 Panel + 1 Zone 13: Input 5 Zone 13: Panel Input 5B
Zone 14: Input 1 Jumper Zone 14: Input 4 Zone 14: Input 6 Zone 14: Panel Input 6B
Zone 15: Input 2 Panel + 1 Zone 15: Input 5 Zone 15: Input 7 Zone 15: Panel Input 7B
ZX8 Zone 16: Input 3 Zone 16: Input 6 Zone 16: Input 8 Zone 16: Panel Input 8B
Jumper Zone 17: Input 4 Zone 17: Input 7 Zone 17: Input 1 Zone 17: Input 1
Panel + 9 Zone 18: Input 5 Zone 18: Input 8 Zone 18: Input 2 Zone 18: Input 2
Zone 19: Input 6 Zone 19: Input 1 ZX8 Zone 19: Input 3 ZX8 Zone 19: Input 3
Zone 20: Input 7 Zone 20: Input 2 Jumper Zone 20: Input 4 Jumper Zone 20: Input 4
Zone 21: Input 8 ZX8 Zone 21: Input 3 Panel + 9 Zone 21: Input 5 Panel + 1 Zone 21: Input 5
Zone 22: Input 1 Jumper Zone 22: Input 4 Zone 22: Input 6 Zone 22: Input 6
Zone 23: Input 2 Panel + 9 Zone 23: Input 5 Zone 23: Input 7 Zone 23: Input 7
ZX8 Zone 24: Input 3 Zone 24: Input 6 Zone 24: Input 8 Zone 24: Input 8
Jumper Zone 25: Input 4 Zone 25: Input 7 Zone 25: Input 1 Zone 25: Input 1
Panel + 17 Zone 26: Input 5 Zone 26: Input 8 Zone 26: Input 2 Zone 26: Input 2
Zone 27: Input 6 Zone 27: Input 1 ZX8 Zone 27: Input 3 ZX8 Zone 27: Input 3
Zone 28: Input 7 ZX8 Zone 28: Input 2 Jumper Zone 28: Input 4 Jumper Zone 28: Input 4
Zone 29: Input 8 Jumper Zone 29: Input 3 Panel + 17 Zone 29: Input 5 Panel + 9 Zone 29: Input 5
Zone 30: N/A Panel + 17 Zone 30: Input 4 Zone 30: Input 6 Zone 30: Input 6
Zone 31: N/A Zone 31: Input 5 Zone 31: Input 7 Zone 31: Input 7
Zone 32: N/A Zone 32: Input 6 Zone 32: Input 8 Zone 32: Input 8
SP7000 No ATZ SP7000 ATZ
Zone 1: Panel Input 1 Zone 1: Panel Input 1A
Zone 2: Panel Input 2 Zone 2: Panel Input 2A
Zone 3: Panel Input 3 Zone 3: Panel Input 3A
Zone 4: Panel Input 4 Zone 4: Panel Input 4A
Zone 5: Panel Input 5 Zone 5: Panel Input 5A
Zone 6: Panel Input 6 Zone 6: Panel Input 6A
Zone 7: Panel Input 7 Zone 7: Panel Input 7A
Panel Zone 8: Panel Input 8 Zone 8: Panel Input 8A
Zone 9: Panel Input 9 Zone 9: Panel Input 9A
Zone 10: Panel Input 10 Zone 10: Panel Input 10A
Zone 11: Panel Input 11 Zone 11: Panel Input 11A
Zone 12: Panel Input 12 Zone 12: Panel Input 12A
Zone 13: Panel Input 13 Zone 13: Panel Input 13A
Zone 14: Panel Input 14 Zone 14: Panel Input 14A
Zone 15: Panel Input 15 Zone 15: Panel Input 15A
Zone 16: Panel Input 16 Panel Zone 16: Panel Input 16A
Zone 17: Input 1 Zone 17: Panel Input 1B
Zone 18: Input 2 Zone 18: Panel Input 2B
ZX8 Zone 19: Input 3 Zone 19: Panel Input 3B
Jumper Zone 20: Input 4 Zone 20: Panel Input 4B
Panel + 1 Zone 21: Input 5 Zone 21: Panel Input 5B
Zone 22: Input 6 Zone 22: Panel Input 6B
Zone 23: Input 7 Zone 23: Panel Input 7B
Zone 24: Input 8 Zone 24: Panel Input 8B
Zone 25: Input 1 Zone 25: Panel Input 9B
Zone 26: Input 2 Zone 26: Panel Input 10B
ZX8 Zone 27: Input 3 Zone 27: Panel Input 11B
Jumper Zone 28: Input 4 Zone 28: Panel Input 12B
Panel + 9 Zone 29: Input 5 Zone 29: Panel Input 13B
Zone 30: Input 6 Zone 30: Panel Input 14B
Zone 31: Input 7 Zone 31: Panel Input 15B
Zone 32: Input 8 Zone 32: Panel Input 16B
SP5500 No ATZ SP5500 ATZ SP6000 No ATZ SP6000 ATZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 and is the answer not in the manual?

Paradox Magellan MG5050 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256
Built-in TransceiverYes
Remote ControlYes
Wireless KeypadsYes
StayD ModeYes
RemotesUp to 32
Power Supply16.5 VAC
Zones32
Battery Backup7Ah