Timers
Zone Timers (MG Series)
Zone Timers (SP Series)
System Timers
Section MG5000 MG5050 Data Description (Default 060)
[041] Zone 1 (Z1): (Z1): ____/____/____ (000 to 255) x 10ms Hardwire Zone 1 Speed
[042] Zone 2 (Z2): (Z2): ____/____/____ (000 to 255) x 10ms Hardwire Zone 2 Speed
[043] Zone 3 (Z1 with ATZ): (Z3): ____/____/____ (000 to 255) x 10ms Hardwire Zone 3 Speed
[044] Zone 4 (Z2 with ATZ): (Z4): ____/____/____ (000 to 255) x 10ms Hardwire Zone 4 Speed
[045] Zone 5 (Z5): ____/____/____ (000 to 255) x 10ms Hardwire Zone 5 Speed
[046] Zone 6 (Z1 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 6 Speed
[047] Zone 7 (Z2 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 7 Speed
[048] Zone 8 (Z3 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 8 Speed
[049] Zone 9 (Z4 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 9 Speed
[050] Zone 10 (Z5 with ATZ): ____/____/____ (000 to 255) x 10ms Hardwire Zone 10 Speed
[051] Zone 11 ____/____/____ (000 to 255) x 10ms Hardwire Zone 11 Speed
[052] Zone 12 ____/____/____ (000 to 255) x 10ms Hardwire Zone 12 Speed
[053] Zone 13 ____/____/____ (000 to 255) x 10ms Hardwire Zone 13 Speed
[054] Zone 14 ____/____/____ (000 to 255) x 10ms Hardwire Zone 14 Speed
[055] Zone 15 ____/____/____ (000 to 255) x 10ms Hardwire Zone 15 Speed
[056] Zone 16 ____/____/____ (000 to 255) x 10ms Hardwire Zone 16 Speed
Section SP5500 SP6000 SP7000* Data Description (Default 060)
[041] Zone 1 (Z1): (Z1): (Z1): ____/____/____ (000 to 255) x 10ms Hardwire Zone 1 Speed
[042] Zone 2 (Z2): (Z2): (Z2): ____/____/____ (000 to 255) x 10ms Hardwire Zone 2 Speed
[043] Zone 3 (Z3): (Z3): (Z3): ____/____/____ (000 to 255) x 10ms Hardwire Zone 3 Speed
[044] Zone 4 (Z4): (Z4): (Z4): ____/____/____ (000 to 255) x 10ms Hardwire Zone 4 Speed
[045] Zone 5 (Z5): (Z5): (Z5): ____/____/____ (000 to 255) x 10ms Hardwire Zone 5 Speed
[046] Zone 6 (Z1 with ATZ): (Z6): (Z6): ____/____/____ (000 to 255) x 10ms Hardwire Zone 6 Speed
[047] Zone 7 (Z2 with ATZ): (Z7): (Z7): ____/____/____ (000 to 255) x 10ms Hardwire Zone 7 Speed
[048] Zone 8 (Z3 with ATZ): (Z8): (Z8): ____/____/____ (000 to 255) x 10ms Hardwire Zone 8 Speed
[049] Zone 9 (Z4 with ATZ): (Z1 with ATZ): (Z9): ____/____/____ (000 to 255) x 10ms Hardwire Zone 9 Speed
[050] Zone 10 (Z5 with ATZ): (Z2 with ATZ): (Z10): ____/____/____ (000 to 255) x 10ms Hardwire Zone 10 Speed
[051] Zone 11 (Z3 with ATZ): (Z11): ____/____/____ (000 to 255) x 10ms Hardwire Zone 11 Speed
[052] Zone 12 (Z4 with ATZ): (Z12): ____/____/____ (000 to 255) x 10ms Hardwire Zone 12 Speed
[053] Zone 13 (Z5 with ATZ): (Z13): ____/____/____ (000 to 255) x 10ms Hardwire Zone 13 Speed
[054] Zone 14 (Z6 with ATZ): (Z14): ____/____/____ (000 to 255) x 10ms Hardwire Zone 14 Speed
[055] Zone 15 (Z7 with ATZ): (Z15): ____/____/____ (000 to 255) x 10ms Hardwire Zone 15 Speed
[056] Zone 16 (Z8 with ATZ): (Z16): ____/____/____ (000 to 255) x 10ms Hardwire Zone 16 Speed
* SP7000: For zones 17-32 (ATZ), the zone timer is set at 0.6 seconds.
Section Data Description
[710] ____/____/____ (000 to 255) seconds Entry delay 1 (default 045)
[711] ____/____/____ (000 to 255) seconds Entry delay 2 (default 045)
[712] ____/____/____ (000 to 015) Auto zone shutdown counter (Default 005)
[713] ____/____/____ (000 to 255) seconds Intellizone delay (default 048)
[714] ____/____/____ (000 to 255) minutes Recycle alarm delay (default 000)
[715] ____/____/____ (000 to 255) Recycle alarm counter (default 000)
[716] ____/____/____ (000 to 255) minutes Keypad lockout delay (default 000)
[717] ____/____/____ (000 to 255) attempt before locking Keypad lockout counter (default 000)
[718] ____/____/____ (000 to 255) seconds Remote panic disarm lock delay (default 000)