23 Programming Guide
System Programming
[700] General System Options
Option OFF ON
[1]
Partitioning
N Disabled N Enabled
[2]
Battery charging (350mA or 700mA)
N 350mA N 700mA
[3]
Audible trouble warning (except AC failure)
N Disabled N Enabled
[4]
Audible trouble warning on AC failure
N Disabled N Enabled
[5]
RF jamming supervision
N Disabled N Enabled
[6]
Exit delay termination
N Disabled N Enabled
[7]
Tamper supervision on the bus module
N Disabled N Enabled
[8] N/A N/A N/A
[701] General System Options
Option OFF ON
[1]
Access code length
N 6 digits N 4 digits
[2]
Lock master code
N Disabled N Enabled
[3]
Confidential mode
N Disabled N Enabled
[4]
To exit confidential mode
N Enter a code N Press a key
[5]
Confidential mode timer
N 2 minutes N 5 seconds
[6]
REM2 version number
N REM2 V2.00 N REM2 V2.01 or higher
[7]
Display entry delay on LCD keypad (K32LCD)
N Disabled N Enabled
[8]
Display exit delay on LCD keypad (K32LCD)
N Disabled N Enabled
[702] Panic Options
Option OFF ON
[1]
Panic 1
N Disabled N Enabled
[2]
Panic 2
N Disabled N Enabled
[3]
Panic 3
N Disabled N Enabled
[4]
Panic 1: Report only or audible alarm
N Report only N Audible
[5]
Panic 2: Report only or audible alarm
N Report only N Audible
[6]
Panic 3: Report only or audible alarm
N Report only N Audible
[7] & [8] N/A N/A N/A
[703] Arming/Disarming Options 1
Option OFF ON
[1]
One-touch regular arming
N Disabled N Enabled
[2]
One-touch stay arming
N Disabled N Enabled
[3]
One-touch sleep arming
N Disabled N Enabled
[4]
One-touch bypass programming
N Disabled N Enabled
[5]
Restrict arming on battery failure
N Disabled N Enabled
[6]
Restrict arming on tamper failure (Zone + Bus Module
+ Wireless PGM)
N Disabled N Enabled
[7] Restrict arming on wireless supervision trouble (Zone + Bus
Module + Wireless PGM)
N Disabled N Enabled
[8]
Calling the VDMP3
N Disabled N Enabled

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 and is the answer not in the manual?

Paradox Magellan MG5050 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256
Built-in TransceiverYes
Remote ControlYes
Wireless KeypadsYes
StayD ModeYes
RemotesUp to 32
Power Supply16.5 VAC
Zones32
Battery Backup7Ah

Related product manuals