Magellan / Spectra SP 24
[704] Arming/Disarming Options 2
Option OFF ON
[1]
Regular arming switches to force arming
N Disabled N Enabled
[2]
Stay arming switches to stay force arming
N Disabled N Enabled
[3]
Sleep arming switches to sleep force arming
N Disabled N Enabled
[4]
Bell squawk when arm/disarm with remote
N Disabled N Enabled
[5]
Bell squawk when arm/disarm with a keypad
N Disabled N Enabled
[6]
Beep on exit delay
N Disabled N Enabled
[7] No exit delay beeps and no bell squawk when stay/sleep
arm
N Disabled N Enabled
[8]
No exit delay when arm with a remote
N Disabled N Enabled
[705] General Zone Options 1
Option OFF ON
[1]
ATZ zone doubling
N Disabled N Enabled
[2]
ATZ wiring options
N Series N Parallel
[3] & [4] Tamper Recognition
[5]
Generate tamper on bypassed zone
N No N Yes
[6] & [7] Supervision Options
[8]
Generate supervision on bypassed zone
N No N Yes
[706] General Zone Options 2
Option OFF ON
[1]
Check-in supervision time
N 24 hours N 80 minutes
[2]
EOL resistors
N Disabled N Enabled
[3]
Zone Input 1 becomes a 2-wire smoke input (except SP5500)
N Disabled N Enabled
[4]
ZX8 ID A (Panel + 1) Input 1
N Zone input N Tamper input
[5]
ZX8 ID B (Panel + 9) Input 1
N Zone input N Tamper input
[6]
ZX8 ID C (Panel + 17) Input 1
N Zone input N Tamper input
[7] N/A N/A N/A
[8] N/A N/A N/A
[3] [4]
RF Zone/Hardwired Zone Tamper Recognition Options Keypad / Bus Module Tamper Recognition Options*
OFF OFF Disabled Disabled
OFF ON
TROUBLE ONLY TROUBLE ONLY
ON OFF When disarmed: TROUBLE ONLY
When armed: Follow zone’s alarm type
TROUBLE ONLY
ON ON When disarmed: AUDIBLE ALARM
When armed: Follow zone’s alarm type
AUDIBLE ALARM
* Tamper recognition of keypad / bus module only if section [700] option [7] is enabled.
[6] [7]
RF Zone Supervision Options Keypad / Bus Module Supervision Options
OFF OFF Disabled Disabled
OFF ON
TROUBLE ONLY TROUBLE ONLY
ON OFF When disarmed: TROUBLE ONLY
When armed: Follow zone’s alarm type
TROUBLE ONLY
ON ON When disarmed: AUDIBLE ALARM
When armed: Follow zone’s alarm type
AUDIBLE ALARM