EasyManua.ls Logo

Paradox Magellan MG5050

Paradox Magellan MG5050
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25 Programming Guide
Other Settings and Modes
Partition Programming
Section Description
[950] Reset all programmable sections to factory default values
[955] Clear bus module trouble (remove disconnected module from the bus)
[960] Remote control serial number display (press any button on the assigned remote, then press [ENTER] to view the next digit)
[970] Download memory key into panel (see the Reference & Installation Manual)
[975] Upload panel into the memory key (see the Reference & Installation Manual)
[980] Display version number of the panel (press [ENTER] to view the next digit)
[741] Partition 1 Options
Option OFF ON
[1] Auto-arm on time
N Disabled N Enabled
[2] Auto-arm on no movement
N Disabled N Enabled
[3]& [4]
Auto-arm arming mode
N See Table N See Table
[5] Switch to stay arming if no zone entry delay is opened
N Disabled N Enabled
[6] Follow zones become entry delay 2 when delay zone is bypassed
N Disabled N Enabled
[7]& [8] N/A N/A N/A
[742] Partition 2 Options
Option OFF ON
[1] Auto-arm on time
N Disabled N Enabled
[2] Auto-arm on no movement
N Disabled N Enabled
[3]& [4]
Auto-arm arming mode
N See Table N See Table
[5] Switch to stay arming if no entry delay is opened
N Disabled N Enabled
[6] Follow zones become entry delay 2 when delay zone is bypassed
N Disabled N Enabled
[7]& [8] N/A N/A N/A
[3] [4]
OFF OFF Regular
OFF ON Sleep
ON OFF Stay
[3] [4]
OFF OFF Regular
OFF ON Sleep
ON OFF Stay