EasyManuals Logo

Paradox Magellan MG5050 User Manual

Paradox Magellan MG5050
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
45 Programming Guide
Automatic Report Code List
System Event Default Contact ID Report Code Default SIA Report Code
Arming with User Code (##) 3 4A1 - Close by user CL - Closing report
Auto arming 3 4A3 - Automatic close CA - Automatic closing
Late to close 3 452 - Late to close OT - Late to close
No movement 3 452 - Late to close NA - No activity
Partial arming 1 456 - Group bypass CG - Close area
Quick arming 3 4A8 - Quick arm CL - Closing report
Arm with PC software 3 4A7 - Remote arm/disarm CQ - Remote arming
Disarm with User Code (##) 1 4A1 - Open by user OP - Opening report
Disarm after alarm* with User Code (##) 1 4A1 - Open by user OP - Opening report
Cancel alarm** with User Code (##) 1 4A6 - Cancel by user OR - Disarm from alarm
Auto-arming cancellation 1 464 - Deferred open/close CE - Closing extend
Disarm with PC software 1 4A7 - Remote arm/disarm OQ - Remote disarming
Disarm after an alarm with PC software 1 4A7 - Remote arm/disarm OR - Disarm from alarm
Cancel alarm with PC software 1 4A6 - Cancel by user OR - Disarm from alarm
Cancel paramedic alarm 1 4A6 - Cancel by user MH - Medical alarm restore
Zone bypassed (##) 1 57A - Zone bypass UB - Untyped zone bypass
Zone alarm (##) 1 13A - Burglary alarm BA - Burglary alarm
Fire alarm (##) 1 11A - Fire alarm FA - Fire alarm
Zone alarm restore (##) 3 13A - Burglary alarm restore BH - Burglary alarm restore
Fire alarm restore (##) 3 11A - Fire alarm restore FH - Fire alarm restore
Panic 1 - emergency 1 12A - Panic alarm PA - Panic alarm
Panic 2 - medical 1 1AA - Medical alarm MA - Medical alarm
Panic 3 - fire 1 115 - Pull station FA - Fire alarm
Recent closing 3 459 - Open/Close CR - Recent closing
Global zone shutdown 1 575 - Group bypass CG - Close area
Duress alarm 1 121 - Duress HA - Hold-up alarm
Keypad lockout 1 421 - Access denied JA - User code tamper
Zone shutdown (##) 1 57A - Zone bypass UB - Untyped zone bypass
Zone tampered (##) 1 144 - Sensor tamper TA - Tamper alarm
Zone tamper restore (##) 3 144 - Sensor tamper restore TR - Tamper restoral
AC failure 1 3A1 - AC loss AT - AC trouble
Battery failure 1 3A9 - Battery test failure YT - System battery trouble
Auxiliary supply trouble 1 3AA - System trouble YP - Power supply trouble
Bell output current limit 1 321 - Bell 1 YA - Bell fault
Bell absent 1 321 - Bell 1 YA - Bell fault
Clock lost 1 626 - Time/date inaccurate JT - Time changed
Fire loop trouble 1 373 - Fire trouble FT - Fire trouble
Communication fail 1 354 - Communication fail YC -Fail to communicate
RF jamming 1 344 - RF receiver jam detection XQ - RF Jamming
TLM trouble restore 3 351 - Telco 1 fault restore LR - Phone line restoral
AC failure restore 3 3A1 - AC loss restore AR - AC restoral
Battery failure restore 3 3A9 - Battery test restore YR - System battery restoral
* An armed system is or was in alarm and was disarmed by a user.
** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 and is the answer not in the manual?

Paradox Magellan MG5050 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256
Built-in TransceiverYes
Remote ControlYes
Wireless KeypadsYes
StayD ModeYes
RemotesUp to 32
Power Supply16.5 VAC
Zones32
Battery Backup7Ah

Related product manuals