EasyManuals Logo

Paradox Magellan MG5050 User Manual

Paradox Magellan MG5050
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
Magellan / Spectra SP 28
Communication Programming
[800] Dialer Options
Option OFF ON
[1] & [2]
N See Table N See Table
[3]
Switch to pulse on 5
th
attempt
N Disabled N Enabled
[4] Alternate dial
N Disabled N Enabled
[5] Force dial (must be enabled to comply with TBR-21)
N Disabled N Enabled
[6] DTMF dialing
N Disabled N Enabled
[7]
Pulse ratio
N1:2 N 1:1.5
[8] Reporting
N Dialer activated N No dialer
[801] Dialer Options
Option OFF ON
[1] Report system disarming
N Always N After alarm
[2] Report zone restore
N Bell cutoff N Zone closure
[3] & [4]
[5] Contact ID Override
N Disabled
N CID defaults / slow
format custom
[6] to [8] N/A N/A N/A
[802] Event Call Direction Options 1
Option OFF ON
[1] Call tel. #1 for arm/disarm report codes
N Disabled N Enabled
[2] Call tel. #2 for arm/disarm report codes
N Disabled N Enabled
[3] Call pager for arm/disarm report codes
N Disabled N Enabled
[4] N/A N/A N/A
[5] Call tel. #1 for alarm/restore report codes
N Disabled N Enabled
[6] Call tel. #2 for alarm/restore report codes
N Disabled N Enabled
[7]
Call pager for alarm/restore report codes
N Disabled N Enabled
[8] N/A N/A N/A
Telephone Line Monitoring (TLM) Options
[1] [2]
OFF OFF Disabled
OFF ON When disarmed: Trouble only
When armed: Trouble only
ON OFF When disarmed: Trouble only
When armed: Audible alarm
ON ON Silent alarms become Audible alarm
Auto-Test Report Transmission Options
[3] [4]
OFF OFF Transmit the test report code every time the days programmed in section [840] have elapsed at the time programmed in
section [850] (default).
OFF ON When disarmed: Transmit test report code every time the time programmed in section [852] has elapsed. When armed:
Transmit test report code every time the time programmed in section [851] has elapsed.
ON OFF The control panel will transmit the test report code every hour on the minute value programmed in section [850] (the last
two digits). Note that the first two digits of section [850] will be ignored. E.g. If 10:25 was programmed into section [850],
the test report code would be transmitted at the 25th minute of every hour, i.e. 11:25, 12:25, etc.
ON ON The test report code will be transmitted when any of the conditions of the second and third options listed above (options
[3] = OFF and [4] = ON / options [3] = ON and [4] = OFF) are met.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 and is the answer not in the manual?

Paradox Magellan MG5050 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256
Built-in TransceiverYes
Remote ControlYes
Wireless KeypadsYes
StayD ModeYes
RemotesUp to 32
Power Supply16.5 VAC
Zones32
Battery Backup7Ah