Auxiliary supply trouble restore 3 3AA - System trouble restore YQ - Power supply restored
Bell output current limit restore 3 321 - Bell 1 restore YH - Bell restored
Bell absent restore 3 321 - Bell 1 restore YH - Bell restored
Clock programmed 3 625 - Time/date reset JT - Time changed
Fire loop trouble restore 3 373 - Fire trouble restore FJ - Fire trouble restore
Fail to communicate with monitoring station 3 354 - Fail to communicate YK - Communication fails
RF jamming 3 344 - RF receiver jam detection XH - RF Jamming Restoral
Combus fault 1 333 - Expansion module failure ET - Expansion trouble
Module tamper 1 341 - Expansion module tamper TA - Tamper alarm
Bus fault restore 3 333 - Expansion module failure restore ER - Expansion restoral
Module tamper restore 3 341 - Expansion module tamper restore TR - Tamper restoral
Cold start 1 3A8 - System shutdown RR - Power up
Test report engaged 1 6A2 - Periodic test report TX - Test report
PC software communication finished 1 412 - Successful - download access RS - Remote program success
Installer on site 1 627 - Program mode entry LB - Local program
Installer programming finished 1 628 - Program mode exit LS - Local program success
Maintenance in 1 627 - Program mode entry LB - Local program
Maintenance out 1 628 - Program mode exit LS - Local program success
Closing delinquency 1 654 - System inactivity CD - System inactivity
Module AC fail 1 342 - AC failure on module AT - Module AC fail
Module AC fail restore 3 342 - AC restored on module AR - Module AC fail restore
Module battery fail 1 338 - Battery failure on module YT - Module battery fail
Module battery fail restore 3 338 - Battery failure on module YR - Module battery fail restore
RF Module low battery 1 384 - RF transmitter low battery XT - Transmitter battery trouble
RF Module battery restore 3 384 - RF transmitter battery restore XR - Transmitter battery restoral
RF Module supervision trouble 1 381 - Loss of supervision - RF US - Untype zone supervision
RF Module supervision restore 3 381 - Supervision restore - RF UR - Untyped zone restoral
RF Module supervision lost 1 381 - Loss of supervision- RF US - Untyped Zone Supervisory
RF Module supervision restore 3 381 - Loss of supervision- RF restore UR - Untyped Zone Restoral
RF Module tamper 1 145 - Expansion module tamper ES - Expansion Device Tamper
RF Module tamper restore 3 145 - Expansion module tamper restore EJ - Expansion Device Restore
Paramedic alarm 1 1AA - Medical MA - Medical Alarm
Zone forced 1 57A - Zone forced XW - Zone forced
Zone included 3 57A - Zone included UU - Zone included
Keyswitch arm 34A9 - Keyswitch arm CS - Keyswitch arm
Keyswitch disarm 14A9 - Keyswitch disarm OS - Keyswitch disarm
Keyswitch disarm after alarm 14A1 - Keyswitch disarm after alarm OS - Keyswitch disarm after alarm
Keyswitch cancel alarm 14A6 - Keyswitch cancel alarm OS - Keyswitch cancel alarm
System Event Default Contact ID Report Code Default SIA Report Code