12-1 Applications
650 Series AC Drive
12APPLICATIONS
The Default Application
The drive is supplied with 6 Applications, Application 0 to Application 5. Each Application
recalls a pre-programmed structure of internal links when it is loaded.
Application 0 will not control a motor. Loading Application 0 removes all internal links.
Application 1 is the factory default application, providing for basic speed control
Application 2 supplies speed control using a manual or auto setpoint
Application 3 supplies speed control using preset speeds
Application 4 is a set-up providing speed control with Raise/Lower Trim
Application 5 supplies speed control with Run Forward/Run Reverse
IMPORTANT: Refer to Chapter 5: The Keypad – Special Menu Features to reset the drive to factory
default values which are suitable for most applications.
How to Load an Application
In the menu, go to and press the key twice.
The Applications are stored in this menu.
Use the
keys to select the appropriate Application by number.
Press the
key to load the Application.
Application Description
Control Wiring for Applications
The large Application Diagrams on the following pages show the full wiring for push-button
starting. The diagrams on the reverse show the full wiring for single wire starting.
For the minimum connections to make the drive run refer to Chapter 3: "Installing the Drive" -
Electrical Installation; the remaining connections can be made to suit your system.
When you load an Application, the input and output parameters shown in these diagrams default
to the settings shown. For alternative user-settings refer to the Software Product Manual,
Chapter 1 "Programming Your Application".
normally open contact (relay)
2-position switch
normally open push-button
normally closed push-button
Key to Application Diagrams