14.1 Applicable Standards
EN 61800-3:2004 Adjustable speed electrical power drive systems Part 3: EMC
requirements and specific test methods.
EN 61800-5-1:2007 Adjustable speed electrical power drive systems Part 5-1: Safety
requirements Electrical, thermal and energy.
EN 60204-1:2006 Safety of machinery Electrical equipment of machines Part 1: General
requirements.
EN 61000-3-2:2006 Electromagnetic Compatibility (EMC) - Part 3-2: Limits Limits for
harmonic current emissions (equipment input current up to and including 16A per phase).
IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) Part 3-12: Limits Limits for
harmonic currents produced by equipment connected to public low-voltage systems with input
currents >16A and ≤75A per phase.
EN 61000-6-2:2007 Electromagnetic compatibility (EMC) Part 6-2: General standards
Immunity for industrial environments.
EN 61000-6-3:2007 Electromagnetic compatibility (EMC) Part 6-3: General standards -
Emission standard for residential, commercial and light-industrial environments.
EN 61000-6-4:2007 Electromagnetic compatibility (EMC) Part 6-4: General standards
Emission standard for residential, commercial and light-industrial environments.
RESTRICTION, EVALUATION, AUTHORISATION AND RESTRICTION OF CHEMICALS (REACH)
The Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18
December 2006 concerning the Registration, Evaluation, Authorization, and Restriction of
Chemicals (REACH) entered into force on June 1, 2007. Parker agrees with the purpose of
REACH which is to ensure a high level of protection of human health and the environment.
Parker is compliant with all applicable requirements of REACH.
As of 19
th December 2011 VSD products manufactured and marketed by Parker do not contain
substances on the REACH SVHC candidate list in concentrations greater than 0.1% by weight
per article. Parker will continue to monitor the developments of the REACH legislation and will
communicate with our customers according to the requirement above.
Attention
hot
surfaces
DANGER
Risk of
electric
shock
Caution
Refer to
documentation
Earth/Ground
Protective
Conductor
Terminal
TC-Hydraulik - Rsdorfer Str. 8 - 25746 Heide - Lars Lornsen - T: +49 481 909 - 34 - l.lornsen@tc-hydraulik.de - www.tc-hydraulik.de

Table of Contents

Other manuals for Parker AC10 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC10 series and is the answer not in the manual?

Parker AC10 series Specifications

General IconGeneral
Overload Capacity150% for 60 seconds
Analog Inputs2
Analog Outputs1
Communication OptionsModbus RTU
Protection RatingIP20
Input Voltage200-240VAC, 380-480VAC, 500-575VAC, 600VAC, 690VAC
Digital Outputs2
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Operating Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
DimensionsVaries by model
WeightVaries by model
BrakingBuilt-in dynamic braking