15-10 Parameter Reference
AC10 Inverter
Multi-stage Speed Control: F500-F580
Function
Code
Function
Definition
Setting Range
Mfr’s Value
Change
F500
Stage speed type
0: 3
-stage speed;
1: 15
-stage speed;
2: Max 8
-stage speed auto circulating
1
F501
Selection of Stage Speed
Under
Auto
-circulation Speed Control
2
8
7
F502
Selection of
Times of Auto- Circulation
Speed Control
0
9999when the value is set to 0, the
inverter will carry out infinite circulating
0
F503
Status after
auto circulation running
Finished
0: Stop
1: Keep running at last stage speed
0
F504
Frequency setting for stage 1 speed
F112
F111
5.00Hz
F505
Frequency setting for stage 2 speed
F112
F111
10.00Hz
F506
Frequency setting for stage 3 speed
F112
F111
15.00Hz
F507
Frequency setting for
stage 4 speed
F112
F111
20.00Hz
F508
Frequency setting for stage 5 speed
F112
F111
25.00Hz
F509
Frequency setting for stage 6 speed
F112
F111
30.00Hz
F510
Frequency setting for stage 7 speed
F112
F111
35.00Hz
F511
Frequency setting for stage 8
speed
F112
F111
40.00Hz
F512
Frequency setting for stage 9 speed
F112
F111
5.00Hz
F513
Frequency setting for stage 10 speed
F112
F111
10.00Hz
F514
Frequency setting for stage 11 speed
F112
F111
15.00Hz
F515
Frequency setting for stage 12 speed
F112
F111
20.00Hz
F516
Frequency setting for stage 13 speed
F112
F111
25.00Hz
F517
Frequency setting for stage 14 speed
F112
F111
30.00Hz
F518
Frequency setting for stage 15 speed
F112
F111
35.00Hz
F519
-
F533
Acceleration time setting for the
speeds from
Stage 1
to stage 15
0.1
3000S
Subject to
inverter model
F534
-
F548
Deceleration time setting for the speeds f
rom
Stage 1
to stage 15
0.1
3000S
F549
-
F556
Running directions of stage speeds f
rom
Stage 1
to stage 8
0:
Forward running;
1:
Reverse running
0
F557
-
F564
Running time of stage speeds f
rom
Stage 1
to stage 8
0.1
3000S
1.0S
F565
-
F572
Stop time after finishing stages f
rom
Stage
1
to stage 8.
0.0
3000S
0.0S
F573
-
F579
Running directions of stage speeds f
rom
Stage
9 to stage 15.
0:
Forward running;
1:
Reverse running
0
F580
Reserved
0: Stage speed mode 1
1: Stage speed mode 2
1
TC-Hydraulik - Rsdorfer Str. 8 - 25746 Heide - Lars Lornsen - T: +49 481 909 - 34 - l.lornsen@tc-hydraulik.de - www.tc-hydraulik.de

Table of Contents

Other manuals for Parker AC10 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC10 series and is the answer not in the manual?

Parker AC10 series Specifications

General IconGeneral
Overload Capacity150% for 60 seconds
Analog Inputs2
Analog Outputs1
Communication OptionsModbus RTU
Protection RatingIP20
Input Voltage200-240VAC, 380-480VAC, 500-575VAC, 600VAC, 690VAC
Digital Outputs2
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Operating Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
DimensionsVaries by model
WeightVaries by model
BrakingBuilt-in dynamic braking