Parameter Reference 15-13
AC10 Inverter
Function
Code
Function
Definition
Setting Range
Mfr’s Value
Change
wrong
24: Communication timeout (CE)
45: Communication Timeout (CE)
46:
Flycatching fault (FL)
F711
Fault Frequency of The Latest Malfunction
F712
Fault Current of The Latest Malfunction
F713
Fault PN Voltage of The Latest Malfunction
F714
Fault Frequency of Last Malfunction but One
F715 Fault Current of Last Malfunction but One
F716 Fault PN Voltage of Last Malfunction but One
F717 Fault Frequency of Last Malfunction but Two
F718 Fault Current of Last Malfunction but Two
F719 Fault PN Voltage of Last Malfunction but Two
F720
Record of Overcurrent Protection Fault
Times
F721
Record of Overvoltage Protection Fault
Times
F722 Record of Overheat Protection Fault Times
F723 Record of Overload Protection Fault Times
F724 Input Phase Loss
0: invalid;
1: valid
1
F725 Reserved
F726 Overheat
0: invalid;
1: valid
1
F727 Output Phase Loss
0: invalid;
1: valid
0
F728 Input Phase Loss Filtering Constant
0.160.0
5.0
F730 Overheat Protection Filtering Constant
0.160.0
5.0
F732
Voltage Threshold of Under-voltage
Protection
0~450
Subject to
inverter
model
F737 Over-current 1 Protection
0: Invalid
1:Valid
0
F738 Over-current 1 Protection Coefficient
0.503.00
2.50
F739 Over-current 1 Protection Record
F740 Reserved
F741 Analog Disconnected Protection
0: Invalid
1: Stop and AErr displays.
2: Stop and AErr is not displayed.
3: Inverter runs at the min frequency.
4: Reserved.
0
TC-Hydraulik - Rsdorfer Str. 8 - 25746 Heide - Lars Lornsen - T: +49 481 909 - 34 - l.lornsen@tc-hydraulik.de - www.tc-hydraulik.de

Table of Contents

Other manuals for Parker AC10 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC10 series and is the answer not in the manual?

Parker AC10 series Specifications

General IconGeneral
Overload Capacity150% for 60 seconds
Analog Inputs2
Analog Outputs1
Communication OptionsModbus RTU
Protection RatingIP20
Input Voltage200-240VAC, 380-480VAC, 500-575VAC, 600VAC, 690VAC
Digital Outputs2
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Operating Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
DimensionsVaries by model
WeightVaries by model
BrakingBuilt-in dynamic braking

Related product manuals