Accessories
External ballast resistors
195
Unit
hardware
Connector
assignment / cable
Technical dataConfigurationPositioning and
control functions
Optimization
functions
InterfacesAccessories /
options
StatusParameterError list
Authorised braking impulse power for NMD20 with BRM4/03
1000
10000
100000
0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0
Braking time / s
Pbdyn / W
F=50
F=5
F=10
F=2
F=1
F=0.5
F=20
Authorised braking impulse power for NMD20 with BRM4/02
1000
10000
100000
0,00,20,40,60,81,01,21,41,61,82,02,22,42,62,83,0
Braking time / s
Pbdyn / W
F=50
F=5
F=10
F=2
F=1
F=0.5
F=100
single pulse
F=20
F: Factor
Cooling down time = F *
braking time
F: Factor
Cooling down time = F *
braking time