EasyManua.ls Logo

Parker COMPAX-M /-S (L) - Diagrams

Parker COMPAX-M /-S (L)
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
COMPAX-M / -S
Digital inputs and outputs
154
O6
O6="1" indicates that the axis is at a standstill due to a STOP (I6) or BREAK
(I1&I6).
O6 is reset when the axis moves again.
O16
Only assigned if mark reference is activated (P35=1).
With "0", the mark disappears once the maximum feed length is reached (see
Page 100)
8.6.1.8 Diagrams:
t
t
t
t
tt
tt
t
I3
Jog-
I5
Start
I6
Stop
V
O4
Ready
to Start
O5
Progr. target
pos. reached
O6
Out of action
after stop
0
01 23 4 5 6 78
0 COMPAX ready for new start.
1 When using START at input I5, the outputs O4 and O5 are reset. The axis moves.
2 Interruption using STOP at input I6. After idle, message at output O6 (3).
4 START using I5. Positioning process is continued.
5 Positioning process ended. Message via O4 and O5="1".
6 Manual processing of axis. O5 and O4 ="0".
7 Specification for manual processing ended. Drive decelerates.
8 Manual process ended. Drive at standstill. Ready message for output O4 is set.
Idle after stop
or break
Mark missing
after maximum
feed length
In data record
memory mode
Caption: