11.PROGRAMMING DIGITAL INPUTS AND OUTPUTS
11.1. The pico-PLC
The internal pico-PLC is used to connect the external world (inputs/outputs) with the world of the
parameters of the SLVD-N. The PLC can be used to copy digital input to a binary parameter, to copy a
binary parameter to a digital output and to execute mathematical and Boolean operations. The PLC
program must be inserted as a list of instructions by using the keyboard or by the serial line using a PC
and an interface program. A PLC program (see Appendix F) written to meet the needs of a large
number of applications corresponds to the default parameters (b99.12). In most cases it is not
necessary to program the PLC itself. The main features of the pico-PLC are:
program steps 256
scanning time 6.144 ms
number of timers 2
number of instructions 15
stack depth 1
mathematical operations 16 / 32 bits
fast inputs 2 (512 μs)
PLC PARAMETERS
Par. Description Field Range Def. Res.
Pr71
Constant value = -1. Double word.
R/W -32768÷+32767 -1 1
Pr72
Constant value = 0. Double word.
R/W -32768÷+32767 0 1
Pr73
Constant value = 1. Double word.
R/W -32768÷+32767 1 1
Pr74
Constant value = 2. Double word.
R/W -32768÷+32767 2 1
Pr75
Constant value = 10. Double word.
R/W -32768÷+32767 10 1
Pr76
Constant value = 100. Double word.
R/W -32768÷+32767 100 1
Pr77
Constant value = 1000. Double word.
R/W -32768÷+32767 1000 1
Pr78
Constant value = 1024. Double word.
R/W -32768÷+32767 1024 1
Pr79
Constant value = 4096. Double word.
R/W -32768÷+32767 4096 1
Pr80
Free parameter. A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr81
Free parameter. A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr82
Free parameter. A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr83
Free parameter. A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr84
Free parameter. A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr85
Free parameter. A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr86
Free parameter. A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr87
Parametro libero. Parametro memorizzabile a
disposizione dell’utente (word).
R/W -32768÷+32767 0 1