Parker SLVD7N - 19 Appendix F: Continuous Working

Parker SLVD7N
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin S.p.A S.B.C. Division SLVDN User’s Manual
Page 178 of 181
19.Appendix F: Continuous working
In continuous operation, the limit power depends on the voltage of the supply network and of
the model, see the following table. The data are estimated in order to guarantee 20.000 hours
of service average life of the capacitor.
Maximum continuous power without inductance of network:
Supply network
model
1-phase 3-phase
SLVD1N No derating No derating
SLVD2N 650W No derating
SLVD5N 650W 1100W
SLVD7N 650W 1100W
SLVD10N 1850W No derating
SLVD15N 1850W 4700W
SLVD17N 1850W 4700W
Maximum continuous power with inductance of network:
Supply network
model
1-phase 3-phase
SLVD1N No derating No derating
SLVD2N No derating No derating
SLVD5N 1000W No derating
SLVD7N 1000W 1700W
SLVD10N No derating No derating
SLVD15N 3000W No derating
SLVD17N 3000W 4850W
Data of network inductance:
Supply network
model
1-phase 3-phase
SLVD1N Not necessary Not necessary
SLVD2N 2,5mH 5Arms 14Ap(sat) Not necessary
SLVD5N 2,5mH 6,8Arms 17Ap(sat) 1mH 5,5Arms 11Ap(sat)
SLVD7N 2,5mH 6,8Arms 17Ap(sat) 1mH 5,5Arms 11Ap(sat)
SLVD10N Not necessary Not necessary
SLVD15N 1,2mH 18Arms 45Ap(sat) 0,5mH 15Arms 30Ap(sat)
SLVD17N 1,2mH 18Arms 45Ap(sat) 0,5mH 15Arms 30Ap(sat)