Parker Hannifin S.p.A S.B.C. Division SLVDN User’s Manual
Page 18 of 181
3.4. Technical characteristics
Description UdM
Value
Input and output characteristic
Models - SLVD1N SLVD2N SLVD5N SLVD7N SLVD10N SLVD15N SLVD17N
Rated input current Arms 1,5 2,99 5,99 8,38 11,97 17,96 20,36
Rated output current Arms 1,25 2,5 5 7 10 15 17
Peak output current (2 sec) Arms 2,5 5 10 14 20 30
34
(30@8kHz)
Shaft power kW 0,345 0,7 1,5 2,2 3,0 4,5 5
1ph 0,85 1,5 1,5 1,8 3,0 3,3 3,3 Continuous service installed load
(power derating)
3ph
kVA
0,95 1,6 2,3 3 5,25 6,5 6,5
1ph 3,8 6,5 6,5 7,8 14,3 14,3 14,3 Continuous service input current
(power derating)
3ph
Arms
2,4 4,2 5,9 7,6 13,3 17,2 17,2
Power stage dissipation W 9,3 19,2 52,0 75,1 100,3 158,3 180
Internal fan capacity m
3
/h 39,6 79,0
Switching frequency kHz 4-8 4-8
Output frequency Hz 0 - 450
dynamic braking and intermediate DC circuit
Models - SLVD1N SLVD2N SLVD5N SLVD7N SLVD10N SLVD15N SLVD17N
Internal DC capacitors (±20%)
µF 680 820 1800
Braking resistor internal Ω 40 16
Internal braking power mean W 60 120
Peak internal braking power to 415Vdc kW 4,3 10,7
Max continuous external braking power kW 1 2
Max peak braking current A 11 26
Current mean (internal resistance ) A 0,14 0,29
Current rms (internal resistance) A 1,22 2,73
Max duty cycle (internal resistance) % 1,20 1,10
Braking threshold Vdc 400 - 415
Overvoltage level Vdc 435
Undervoltage level Vdc 135 intervention, 230 restoration