10.1. Decimal parameters
The extended menu is used to set all the following parameters. This menu is invoked by
setting b99.6 to 1 and b99.7 must be set to 0.
Description field: R: read; W: write; M: memory; K: key parameter
Par. Description Field Range Def. Ris.
Pr0
Motor speed: a read-only parameter expressed in
rpm; the Pr0 message is not ever displayed on the
screen. Instead, the message indicating the status
of the converter is displayed.
R ± 15.000
[rpm]
0 1 rpm
Pr1
Analogue reference offset. Expressed as a count
of the input converter.
W ± 10.000
[1=~0.3
mV]
0 1
count
Pr2
First full scale of analogue reference. If b40.0=0
and b40.12=0, the value of Pr7 will be equal to:
Vin Pr2 / 9.76 where Vin is the voltage at the
analogue input.
W ±10000
[rpm]
3000 1 rpm
Pr3
Second full scale of the analogue reference. If
b40.0=0 and b40.12=0, the value of Pr7 will be
equal to:
Vin Pr2 / 9.76 where Vin is the voltage at the
analogue input.
If b42.0=1, b42.1=0, and b42.5=1, Pr3 is the speed
of the virtual axis.
W ±10000
[rpm]
-3000
1 rpm
Pr4
Full scale of frequency reference: (connector
X2). If b40.12=1 and b40.13=1, the value of Pr7
will be the following:
If b42.5=0, Pr7 = Fin Pr4 *2 / 2000000
(frequency/sign signals)
If b42.5=1, Pr7 = Fin Pr4 *2 / 500000
(quadrature signals)
where Fin is the frequency present at the encoder
input:
Fin=enc speed [Rpm] * enc pulses turn / 60
W -32768
÷
+32767
3000 1
Pr5
Internal reference. If b40.12=1 and b40.13=0,
Pr7 will be equal to Pr5.
W ±9000
[rpm]
0 1 rpm
Pr6
Reserved speed reference (read-only): If
b40.2=1, this value is used as a reference for the
speed regulator. The active operating mode will
write its speed request in parameter Pr6.
R ±9000
[rpm]
0 1 rpm
Pr7
Main reference (read-only): If b40.2=0 is used,
Pr7 is the reference for the speed regulator. In
some operating modes Pr7 can be used as a
reference for other values (torque/acceleration)
and in these cases Pr7 will be expressed in the
most suitable unit of measurement.
R
±9000
[rpm]
1 rpm