BRUSH CUTTER EXCELION 2 DH
53_153238-A
7. INCIDENTS AND TROUBLESHOOTING
7.1. TABLE OF INCIDENTS AND BREAKDOWNS - TROUBLESHOOTING
Symptoms
State of the
on/off switch
of the battery
HMI screen Probable cause Checks Solutions Repairer
0 Off Battery is off Battery switch
Switch on your
battery (refer to
Section 5.1.1,
« Power on ».
The pictogram
must be dis-
played on the bat-
tery HMI screen
User
The power
cord is severed
Check the condi-
tion of the cord
Change the cord
Authorised PEL-
LENC distributor
The power cord in-
correctly connected
Checking the
quick connector
Connect the
quick connector
User
Battery
Check that the bat-
tery is not com-
pletely discharged
Recharge
the battery
User
Off
Electronic circuit board
At an authorised PEL-
LENC distributor
Change the elec-
tronic board if
the HMI screen
remains off after
switching on and
checking of the
previous points
Authorised PEL-
LENC distributor
Trigger no longer works
At an authorised PEL-
LENC distributor
Change the trig-
ger or sensor
PELLENC autho-
rised distributor
The tool
does not start
I
On
Electronic circuit board
At an authorised PEL-
LENC distributor
Change the
circuit board
Authorised PEL-
LENC distributor
72