Installing Drivers for 6000 Boards
squares. Use your finger or stylus to touch the red
squares in sequence. After the fifth red point
calibration is complete. To skip, press ‘ESC’.
Advanced
Calibration
Advanced Calibration uses 9, 16 or 25 points to
effectively calibrate touch panel linearity of aged
touchscreens. Click this button and touch the red
squares in sequence with a stylus. To skip, press
‘ESC’.
Command
Calibration
Command call calibration function. Use
command mode call calibration function, this
can uses Standard, 4, 9, 16 or 25 points to
calibrate.
E.g. Please run ms-dos prompt or command
prompt.
c:\Program Files\PenMount Universal
Driver\DMCCtrl.exe -calibration 0 (Standard
Calibration)
DMCCtrl.exe - calibration ($)
0= Standard Calibration
4=Advanced Calibration 4
9=Advanced Calibration 9
16=Advanced Calibration 16
25=Advanced Calibration 25
To calibrate your touchscreen:
1. Please select a device then click “
Configure
”. You can also
double click the device too.
2. Click “
Standard Calibration
” to start standard calibration.