Installer Manual Fleck 3150 - NXT - Programming
58 / 122 Ref. MKT-IM-010 / B - 28.05.2018
REGEN TYPE
TIME CLK
DELAYED
Time clock delayed
(default)
System 4 only.
METER
IMMEDIATE
- All system types.
MTR DLY FIX
RSV
Metered delayed fixed
reserve
Systems 4 & 6 only.
VALVE TYPE
2750 -
2850 -
2900/2910 -
3150 -
3900 -
STAGER-
NOTCH CAM
-
REGENERANT
FLOW
DOWN FLOW -
UP FLOW -
REMOTE SIGNAL
START
OFF to 99
minutes
-
This screen will not be displayed for
system type 14.
DISPLAY
FORMAT
US-
GALLONS
Imperial units (default)
EU-METRIC-
LITERS
Metric units
UNIT CAPACITY 1 to 198’000
Gram CaCO
3
Use the SHIFT button to move to the
left.
CAPACITY
SAFETY FACTOR
0 to 50 %
FEED WATER
HARDNESS
1 to 1’999
Milligram CaCO
3
/L
This screen will only display on the
lead unit for system types 6 & 7. For all
other system types, it will display for
all units.
Use the SHIFT button to move to the
left.
TRIP POINT 1 1 to 3997 L/m This screen will only display for system
14 and will only appear on the master
controller (Valve address #1).
Use the SHIFT button to move to the
left.
TRIP DELAY 1 30 to 99
Second
(30 seconds default)
TRIP POINT 2 1 to 3997 L/m This screen will only display for system
14 and will only appear with the system
sized to 3 or 4 on the master controller
(Valve address #1).
Use the SHIFT button to move to the
left.
TRIP DELAY 2 30 to 99
Second
(30 seconds default)
Parameter Options Definition Note