8.4.9 Operating Temperature
With disabled temperature compensation (see "Temperature compensation" parameter), the 
operating temperature specified here is used to calculate the object distance from the mea-
sured sound propagation time. You can specify a value within the allowable value range.
8.4.10 Foreground Suppression
You can use the "Foreground suppression" parameter to define an area in front of the sensor 
where all received echoes are ignored. The range extends from the transducer surface of the 
sensor up to the distance value specified by this parameter.
By default, the value is set to <End of dead band>.
8.4.11 Background Suppression
You can use the "Background suppression" parameter to specify a range in which incoming 
echoes are discounted. When doing so, the input value represents the start of this range and 
therefore represents the distance from which all incoming echoes are discounted.
Note
This parameter is visible in the DTM advanced view.
Parameter name Access Value range
Operating temperature Read/write -40 ... 100 [°C]
Table 8.27
Note
This parameter is visible in the DTM advanced view.
Parameter name Access Value range
Foreground suppression Read/write <End of dead band> ... <End 
of adjustment range> [mm]
Table 8.28
Note
This parameter is only visible in the DTM advanced view.
Parameter name Access Value range
Background suppression Read/write <Beginning of sensing range> 
... <End of sensing range> 
[mm]
Table 8.29