8.7.2 Local Controls Status
You can use this parameter to check that the programming button on the sensor is working
properly.
If the programming button on the sensor is working properly, the parameter value changes
when the programming button is pressed or released. If the parameter value does not change,
there may be a fault with the programming button.
8.8 Service
8.8.1 Locator Indication
You can use this parameter to switch the locator indication on and off. When locator indication
is activated, the yellow and green LEDs on the sensor flash at the same time with a specific
flashing sequence. This function can be used to localize the sensor in a plant or machine more
easily.
8.8.2 "Reset to Factory Defaults" Button
By pressing this button, you can restore the sensor to its factory settings. When doing so, a
security prompt will initially appear.
Parameter name Access Value range
Local controls status Read only Button not pressed
Button pressed
Table 8.37
Parameter name Access Value range
Locator indication Read/write Disabled
Enabled
Table 8.38