TPD1317e Chapter 11
Page 75
Model M135 Model M130C
Exhaust
Exhaust gas ow 20 m
3
/min (706 ft
3
/min).
Maximum restriction
measured within(305 mm)
12” of turbocharger outlet. 10.2 kPa (3.0” Hg)
Recommended pipe bore
(wet exhaust). 76 mm (3.0”)
Recommended pipe bore
(dry). 63.5 mm (2.5”)
Minimum rise from sea
water level to exhaust
outlet centreline. 203 mm (8.0”)
Lubricating System
Recommended lubricating
oil. AP1 CC/SE
API CD/SE or CCMC D4 can also be used but
are not recommended for rst 20/40 hours
Sump capacity maximum 15 litres (3.3 gallons)
Maximum installation
angle plus planing
angle for continuous
operation. 17
o
engine front up + 3
o
rise. 5
o
nose down + 3
o
rise with special kit of parts, 30
o
heel
Oil pressure, in operating
speed range (steady state). 280 kN/m
2
(40 psi)
Low oil pressure
switch setting. 83 kN/m
2
(12 psi)
Electrical System
Alternator Lucas A127 40A (24V) or 70A (12V).
Starter type CAV CA45H
Number of teeth in ywheel 126
Number of teeth on starter 10
Cold Start Limits
Minimum cold start
temperature (with aid). -15
o
C (5
o
F)
Batteries for minimum 2 off - 315 Amps to BS3911 or
cold start 2 off - 535 Amps to SAE J537