Adjustment
13 - 38
600
601
608 RESET
SWITCH OFF
13.38 Cold start
When a cold start is carried out, all newly created or altered programs, as well
as altered parameter settings are deleted!
The machine is set back to its condition at the time of delivery.
The altered programs or parameter settings can be stored separately with the
PC-program SAM, see Chapter 13.42 Data backup and protection with PC-
program SAM.
● Switch on the machine.
● Switch to parameter input (LED in the key is not on).
● Select the function group "600" with the corresponding plus/minus key.
● Confirm input with Enter.
● Enter the code, see Chapter 11.03.02 Entering/altering the access code.
● With the corresponding plus/minus key select e.g. parameter "608" (carry out cold start).
● Confirm input with Enter.
● Switch off the machine twice and on again after about 3 seconds.