Input P40 ED
38
Group
Parameter
Description
Machine type
User level
Setting range
Set value
6
642 Presser foot lift time from switch-on to
tension reduction
1, 2, 3, 4, 5 B 10 - 150 100
643 Feed adjustment time from switch on
to tension reduction
1, 2, 3, 4, 5 B 10 - 150 100
644 Number of knotting stitches
1, 2, 3, 4, 5 B 0 - 20
0
646 Seam end cycle without trimming 1, 2, 3, 4, 5 B ON - OFF OFF
651 Automatic lowering of presser foot at
machine standstill
1, 2, 3, 4, 5 B ON - OFF ON
653 Bearing position before sewing 1, 2, 3, 4, 5 B ON - OFF OFF
660 Bobbin thread monitoring
0 = OFF,
1 = by sensor
2 = by stitch counting
1, 2, 3, 4, 5 B 0 - 2 0
668 Thread wiper 1, 2, 3, 4, 5 B ON - OFF OFF
680 Start inhibitor when drive is running
and machine is tilted back
ON = Error 92 appears on the display.
After the machine has been set
in an upright position, the drive
must be switched off then on
again. The start inhibitor function
is then out of action.
OFF = Error 9 appears on the display
. After the machine has been set
in an upright position, the start
inhibitor function is out of action
1, 2
3, 4, 5
B
-
ON - OFF
-
ON
-
694 Max. speed for angle-controlled
switching for thread tension release
1, 2, 3
4,5
-
B
-
300 - 800
-
500
7
700* Needle position 0
Needle reference position
1, 2, 3, 4
5
B
B
0 - 255
0 - 255
0
10
702* 1st needle position (lowered) 1
2
3, 4, 5
B
B
B
0 - 255
0 - 255
0 - 255
90
15
80
* = These parameters remain unchanged when the set parameter values are reset,
see Chapter 10.01 Reset / Cold start.