Input P40 ED
40
Group
Parameter
Description
Machine type
User level
Setting range
Set value
7
746 Needle position for switchover
Zig-zag or triple stitch
1
2, 3, 4, 5
B
-
0 - 255
-
90
-
748 Input E 3 is:
1 = needle raised without trimming
2 = needle position change
3 = single stitch
4 = single stitch with shortened
stitch length
5 = tack inversion
6 = tack suppression
7 = switchover position
8 = raise puller off
9 = alteration of needle position step by
step forwards
10 = alteration of needle position step
by step in reverse
1, 2, 3, 4, 5 B 1 - 10 5
757 Stop position for ornamental tack 1, 3, 4, 5,
2
-
B
-
0 - 255
-
25
760 Remaining no. of stitches after reaction
of bobbin thread monitor during bobbin
thread monitoring
1 = Multiplying factor for fi xed
value x 10 during direct monitoring
2 = Multiplying factor for fi xed
value x 200 during indirect
monitoring
1, 2, 3, 4, 5 A 0 - 250 5
761 Extension thread tension release /
thread pulling [ms]
1, 2, 3, 4, 5 B
-
0 - 80
-
0
-
762 Switch on angle for thread tension
release
1, 2, 3,
4, 5
-
B
-
0 - 255
-
196
763 Switch off angle for thread tension
release
1, 2, 3,
4, 5
-
B
-
0 - 255
-
1
770 Lifting delay for presser foot when
pedal position is "-1" [ms]
1, 2, 3, 4, 5 B 10 - 250 80
* = These parameters remain unchanged when the set parameter values are reset,
see Chapter 10.01 Reset / Cold start.