Input P70 ED
52
Group
Parameter
Description
Machine type
User level
Setting range
Set value
7
725 Control panel display
ON = actual speed
OFF = remaining stitches for bobbin
thread
1, 2, 3 B ON - OFF ON
726 Counter for bobbin monitoring 1, 2, 3 B ON - OFF OFF
727 Counter for bobbin monitoring effective-
ON = stop and signal on output
OFF = signal on output without stop
1, 2, 3 B ON - OFF OFF
729 Start delay after lowering presser
foot [ms]
1, 2, 3 B 10 - 2550 140
730 Lift delay for presser foot at end of
seam
1, 2, 3 B 0 - 2000 50
747 Operating mode for thread clamp
ON = pneumatic, OFF = electric
1, 2, 3 B ON - OFF OFF
760 Remaining no. of stitches after reaction
of bobbin thread monitor during bobbin
thread monitoring
1 = Multiplying factor for fi xed
value x 10 during direct monitoring
2 = Multiplying factor for fi xed
value x 200 during indirect
monitoring
1, 2, 3 A 0 - 250 10
761 Extension thread tension release /
thread pulling [ms]
1, 2, 3 B 0 - 3000 0
769 Remaining number of stitches for
stitch counter(indirect bobbin thread
monitoring)
1, 2, 3 B 1 - 2550 100
770 Lifting delay for presser foot when
pedal position is "-1" [ms]
1, 2
3
B
B
10 - 2550
10 - 2550
50
100
772 Operating mode trimming
ON = with shortened trim stitch trim-
ming always with short stitch length
(parameter 988 = ON)
OFF = standard trimming
1, 2, 3 B ON - OFF OFF
* = These parameters remain unchanged when the set parameter values are reset,
see Chapter 10.01 Reset / Cold start.