P70 ED Input
53
Group
Parameter
Description
Machine type
User level
Setting range
Set value
7
774 Needle position raised for thick
material(with pedal)
ON = t.d.c. needle (parameter 710)
OFF = t.d.c. thread take-up lever
(parameter 703)
1, 2, 3 B ON - OFF OFF
775 Stop time for ornamental tack [ms] 1, 2, 3 B 10 - 2550 200
777 Reset duration for bobbin thread monitor 1, 2, 3 B 10 - 500 100
778 Blowing time for cleaning thread moni-
tor [ms]
1, 2, 3 B 10 - 5000 100
789 Needle position 10 (bearing position) 1, 2, 3 B 0 - 255 225
790 Program selection for machine type 1, 2
3
B
B
1 - 4
1 - 7
▲
▲
793 Delay for feed adjustment on till trim-
ming with shortened trim stitch [ms)
1, 2, 3 B 0 - 2550 140
797 Hardware test 1, 2, 3 C ON - OFF OFF
798 User level
0 = user level A
1 = mechanic level B
11 = service level C
1, 2, 3 A 0 - 20 0
799* Selected machine class(see Table of
machine types on Pages 44 - 45)
1
2
3
C
C
C
1
2
3
1
2
3
8
800* Motor rotating direction when looking
at V-belt pulley
1= anti-clockwise, 0 = clockwise
1, 2, 3 C 0 - 1 1
801 Reversing angle at end of seam 1, 2, 3 B 10 - 200 30
814 Change-over of positioning method
1 = Ramp braking in target position
2 = Max. braking at positioning speed
and wait till target position is
reached.
1, 2, 3 C 1 - 2 1
* = These parameters remain unchanged when the set parameter values are reset,
see Chapter 10.01 Reset / Cold start.
▲